INFRATEK Switzerland 106A Power Analyzer




106A Single- and Three Phase Power Analyzers

Press for large image (148kB) Press for large image (148kB) Press for large image (148kB) Press for large image (148kB)

Features...

  • Suitable for frequency inverter drivers
  • Large, bright display for 10 or 40 values
  • DC-1MHz, 1.5mA-40A, 0.3V-1000V
  • 0.1% and 0.05% accuracy

...more Features

  • Scope function, Bar charts, Harmonics 1-99
  • IEEE-488, RS232, Analog outputs / inputs
  • Windows Operating Software
106A Models Specifications Screen Shots Datasheet

Introduction

The Infratek 106A high precision broadband Power Analyzer has a wide current range 1mA-40A designed to offer the engineer the ability to measure low stand by power, power at low power factor of an idling transformer, or power of a frequency inverter driving a large motor.

The Infratek 106A high performance Power Analyzers are available as single- and three phase instruments. The 106A is designed to cope with the extreme signals generated on frequency inverter drivers and other electronically generated signals. You don't have to worry about the signal waveforms. The analyzers will always provide precise and reliable measurements.The large and very bright monitor lets you read the display values from a distance of up to 4m.

Simple to use

From checking power of your coffee machine to determining the pertinent power parameters of a frequency inverter driven system is a simple task. You have all values displayed. In large letters by the way, well readable, even in dark rooms. The user menu makes operation easy. The measured values you can either print, send them to a PC via IEEE- or RS232 interface, or to a chart recorder via the analog outputs. You can have all available options installed in your instrument.

Extraordinary features

Infratek has put much effort into the design of the 106A Power Analyzers to give you highest performance at low costs.The analyzer inputs are all galvanically isolated, are broadband DC-1MHz, have a wide input range (0.3 V-1000 V, 1.5 mA-40 A), and have an exceptional common mode rejection for use in frequency inverter driven systems. The accuracy is 0.1 % (0.05 % versions are available). The bright LCD monitor displays up to 10 measured values in well legible 9mm high numbers. The Three Phase Power Analyzer puts up to 40 measured values on the screen. The Windows operating software lets you configure all parameters of the instrument. The user sets the measured quantities he wants to read from the Power Analyzer, this includes for example, 8 analog inputs. Special software is available for motor- and transformer testing. Also, an extensive LabView driver is available.



Top

106A Single- and Three Phase Power Analyzers

Product Description
106A-1/0.1 Single Phase Power Analyzer, 0.1% accuracy,
nonvolatile memory to save 20 instrument settings.
0.3V-1000V, 1mA-30A, shunt input.
106A-1/0.05 Single Phase Power Analyzer, 0.05% accuracy,
nonvolatile memory to save 20 instrument settings.
0.3V-1000V, 1mA-30A, shunt input.
106A-1/nh Single Phase Power Analyzer, without harmonics without graphics, 0.1% accuracy, nonvolatile memory to save 20 instrument settings. 0.3V-1000V, 1mA-30A, shunt input.
106A-3/0.1 Three Phase Power Analyzer, 0.1% accuracy,
nonvolatile memory to save 20 instrument settings.
0.3V-1000V, 1mA-30A, shunt input.
106A-3/0.05 Three Phase Power Analyzer, 0.05% accuracy,
nonvolatile memory to save 20 instrument settings.
0.3V-1000V, 1mA-30A, shunt input.
106A-3/nh Three Phase Power Analyzer, without harmonics without graphics, 0.1% accuracy, nonvolatile memory to save 20 instrument settings. 0.3V-1000V, 1mA-30A, shunt input.

Accessories

Accessory Description
ACS1 Current clamp with connector to 106A shunt input; 0-200A / 0-1000A, DC-1kHz, Basic accuracy 2%. Other ranges and accuracies on request.
ACS2 Portable printer (106 x 180 x 88mm) with Centronics interface and cable (400gr.)
ACS3 Soft carrying case for 106A
ACS4 Set of test leads, max. 32A, 1.5m (2 red; 2 black)
ACS5 Shunt input connector
ACS6 Service Manual 106A
ACS7 Rack Mounting Kit
ACS8 Official Calibration Certificate from SCS (Swiss Calibration Service)
ACS10 RS232 - USB Adapter cable, USB 1.1 compatible, Windows 98/2000/ME/XP, > 1Mbps data transfer rate
ACS11 RS232 - Ethernet Adapter

Options

Option Description
01 RS-232 Interface and Centronics printer output incl. Windows Operating Software (95 - Vista) to control, read and store data.
02 RS-232 and IEEE-488 Interface, Centronics printer output incl. Windows Operating Software (95 - Vista) to control, read and store data.
03 RS-232 and IEEE-488 Interface, Centronics printer output and 4 programmable analog outputs, 8 analog inputs incl. Windows Operating Software (95 - Vista) to control, read and store data.
04 3-Phase current sensor module 0-100A (supply by 106A)
06 106A driver for Nat. Instrument LabView
07/M Software for Motor Testing
07/T Software for Transformer Testing
08 TTL-input for external synchronisation
09 Network to form artificial neutral (maily frequency inverter measurements)
10 0-300A, 0-3000A flexible current clamps with connector to clamp input of Power Analyzer (1 per phase)
Basic accuracy: 1% at 50/60Hz





Top

106A Specification

Voltage Ranges, 8 ranges 1-3-10-sequence; 0.3V, 1V, 3V, 10V, 30V, 100V, 300V, 1000V -
Frequency range DC, 0.1Hz-1MHz
Crest Factor 3:1 at 50% full scale (fs)
Input Impedance >1MΩ
Common Mode - 50Hz/100kHz 160dB/100dB
Standard accuracy 23°C; rms, mean, rectified mean; 0.3V typical
1Hz-1kHz =           ±(0.1% rdg + 0.1% range)
DC, 1kHz-10kHz = ±(0.2% rdg + 0.2% range)
10kHz-100kHz =    ±(0.3% range + 0.04%/kHz rdg)
100kHz-300kHz =  ±(0.3% range + 0.04%/kHz rdg), typical
Improved accuracy
±(0.05% rdg + 0.07% range )
Current 13 Ranges: 1.5mA, 5mA, 15mA, 50mA, 150mA, 500mA, 1.5A, 5A; 1A, 3A, 10A, 30A, 100A Max. 1A, 5A, 30A, resp.
Frequency range DC, 0.1Hz-300kHz / 1MHz
Crest Factor 3:1 at 50% full scale (fs)
Common Mode - 50Hz/100kHz 160dB/120dB
Standard accuracy 23°C;
1Hz-1kHz
DC, 1kHz-10kHz
10kHz-100kHz
100kHz-300kHz
1A-, 5A-, shunt input
±(0.1% rdg + 0.1% range)
±(0.2% rdg + 0.2% range)
±(0.3% rdg + 0.04%/kHz rdg)
±(0.3% rdg + 0.04%/kHz rdg),
30A input
±(0.1% rdg + 0.1% range)
±(0.7% rdg + 0.2% range)
±(0.3% rdg + 0.5%/kHz rdg), typ.
typical
Lowest ranges 1.5mA, 15mA
1A typical.
Improved accuracy 1Hz-400Hz
±(0.05% rdg + 0.07% range)
Power 104 ranges corresponding to the products V x A -
Frequency range DC, 0.1Hz-300kHz
Accuracy 23°C ±3°C
45Hz-65Hz                 ±(0.1% rdg + 0.01% range)
1Hz-1kHz                  Add accuracy percentage figures of current and voltage
DC, 1kHz-10kHz        +0.04%/kHz PF
10kHz-100kHz

PF = 0 to ±0.1
PF = 0 to ±1
PF = 0 to ±1
PF = 1
Frequency 0.1Hz-400kHz, V triggered; Accuracy ±0.1% -
Computed Values Accuracy; Reactive Power, Var = ±(VA² - W²)½; Apparent Power: VA = Arms Vrms;
Power Factor: PF = W/VA; Crest Factor: CF = Ap/Arms, Vp/Vrms; Form Factor:
FF = At/Arms, Vt/Vrms; Impedance: Z = Vrms/Arms;
Total Harm Dist: THD = (Irms² - IFund²)½/Irms
Add accuracy percentage
figures of values involved
in computation.
Integrator Energy, Charge; Accuracy - Wh, VAh, Varh, Ah; Basic accuracy of integrated quantity. -
Harmonic Analysis Frequency range of fundamental - 2.5Hz-100kHz -
Range of harmonic 1-99
Accuracy, Harmonic current and voltage
2Hz-1kHz =        ±(0.1% rdg + 0.1% range)
1kHz-10kHz =     ±(0.5% rdg + 0.5% range)
10kHz-100kHz = ±(0.7% range + 0.1%/kHz rdg),typical
-
Display Blue liquid crystal graphic display with FL backlight; - 64x120mm; - 128x240 pixels -
Power AC, 50-400Hz; Fuse: Power 85V-240V; 2A/15VA
Dielectric Strength Inputs to case or power supply
Line input to case
Input to Input
2.5kV/50Hz/1 minute
1.5kV/50Hz/1 minute
4kV/50Hz/1 minute
Dimension H x W x D; Weight 150 x 235 x 320mm; 4kg
Options IEEE-488-2, RS232, Centronics printer output
4 programmable analog outputs, single-, sum-, or average values
4 Analog inputs 0-±5V, input impedance 200kΩ
4 Analog inputs 0-±10V, input impedance 200kΩ
Rack mounting kit
Windows Operating Software (95 - Vista), transformer-motor testing

0 - ±5V, accuracy 0.2%
0 - ±5V, accuracy 0.2%
0 - ±10V, accuracy 0.2%
1.5mA-1A Inp
Shunt Input
Shunt HiLo 1 A input, mA: 1.5, 5, 15, 50, 150, 500, 1500
Shunt input, mV: 60, 60√10, 600, 600√10, 6000, 6000√10
Input impedance: 60kΩ

1 A input: set scaling to 0.1
Shunt input: 60mV = 1.0000A



Top

106A Screen Shots

IN 5A
15mA    A
1V          A
Sync = I   
> 500ms
VIEW L1

AC

I >________
U >_______
1.0000 A RMS 1.0000 V RMS
1.0000 W ACT 60.0000 Hz FRQ
1.0000 VA APP 1.0000 m PFT
23.9 mA, FFTi

¦ /\   /\  /\
¦/  \/   \/   \/
¦________________
HOLD AC/DC PRINT SPLIT VIEW SETUP

Screen Shot - Measurement Mode (typ.)

Current RMS Mean Rect CF FFT
_ Min Max Peak FF THD
Voltage RMS Mean Rect CF FFT
_ Min Max Peak FF THD
Power Active VAppa VArea Energy FFT
_ _ _ _ _ _
Other Freq PFact ANinp ¦Z¦ /Z

Screen Shot - Measurement Value Table

Scale I +1.000000e+00 Baudrate 9600
Scale V +1.000000e+00 Parity none
Setup Save No 00 End Mode CR+LF
Setup Recall No 00 Protocol Xon
_ _ _ GPIB addr 05
_ _ _ _ _
_ _ _ _ _

Screen Shot - Setup Menu

Back Top