| INFRATEK | Switzerland | 106A Power Analyzer |
|
|
|
|
Features...
|
...more Features
|
| 106A Models | Specifications | Screen Shots | Datasheet |
Introduction |
The Infratek 106A high precision broadband Power Analyzer has a wide current range 1mA-40A designed to offer the engineer the ability to measure low stand by power, power at low power factor of an idling transformer, or power of a frequency inverter driving a large motor. |
The Infratek 106A high performance Power Analyzers are available as single- and three phase instruments. The 106A is designed to cope with the extreme signals generated on frequency inverter drivers and other electronically generated signals. You don't have to worry about the signal waveforms. The analyzers will always provide precise and reliable measurements.The large and very bright monitor lets you read the display values from a distance of up to 4m. |
Simple to use |
From checking power of your coffee machine to determining the pertinent power parameters of a frequency inverter driven system is a simple task. You have all values displayed. In large letters by the way, well readable, even in dark rooms. The user menu makes operation easy. The measured values you can either print, send them to a PC via IEEE- or RS232 interface, or to a chart recorder via the analog outputs. You can have all available options installed in your instrument. |
Extraordinary features |
Infratek has put much effort into the design of the 106A Power Analyzers to give you highest performance at low costs.The analyzer inputs are all galvanically isolated, are broadband DC-1MHz, have a wide input range (0.3 V-1000 V, 1.5 mA-40 A), and have an exceptional common mode rejection for use in frequency inverter driven systems. The accuracy is 0.1 % (0.05 % versions are available). The bright LCD monitor displays up to 10 measured values in well legible 9mm high numbers. The Three Phase Power Analyzer puts up to 40 measured values on the screen. The Windows operating software lets you configure all parameters of the instrument. The user sets the measured quantities he wants to read from the Power Analyzer, this includes for example, 8 analog inputs. Special software is available for motor- and transformer testing. Also, an extensive LabView driver is available. |
106A Single- and Three Phase Power Analyzers
| ||||||||||||||||||||||
Accessories
| ||||||||||||||||||||||
Options
|
| Voltage | Ranges, 8 ranges 1-3-10-sequence; 0.3V, 1V, 3V, 10V, 30V, 100V, 300V, 1000V | - |
| Frequency range | DC, 0.1Hz-1MHz | |
| Crest Factor | 3:1 at 50% full scale (fs) | |
| Input Impedance | >1MΩ | |
| Common Mode - 50Hz/100kHz | 160dB/100dB | |
| Standard accuracy 23°C; rms, mean, rectified mean; 0.3V typical 1Hz-1kHz = ±(0.1% rdg + 0.1% range) DC, 1kHz-10kHz = ±(0.2% rdg + 0.2% range) 10kHz-100kHz = ±(0.3% range + 0.04%/kHz rdg) 100kHz-300kHz = ±(0.3% range + 0.04%/kHz rdg), typical |
Improved accuracy ±(0.05% rdg + 0.07% range ) |
|
| Current | 13 Ranges: 1.5mA, 5mA, 15mA, 50mA, 150mA, 500mA, 1.5A, 5A; 1A, 3A, 10A, 30A, 100A | Max. 1A, 5A, 30A, resp. | ||
| Frequency range | DC, 0.1Hz-300kHz / 1MHz | |||
| Crest Factor | 3:1 at 50% full scale (fs) | |||
| Common Mode - 50Hz/100kHz | 160dB/120dB | |||
|
Lowest ranges 1.5mA, 15mA 1A typical. Improved accuracy 1Hz-400Hz ±(0.05% rdg + 0.07% range) |
|||
| Power | 104 ranges corresponding to the products V x A | - |
| Frequency range | DC, 0.1Hz-300kHz | |
| Accuracy 23°C ±3°C 45Hz-65Hz ±(0.1% rdg + 0.01% range) 1Hz-1kHz Add accuracy percentage figures of current and voltage DC, 1kHz-10kHz +0.04%/kHz PF 10kHz-100kHz |
PF = 0 to ±0.1 PF = 0 to ±1 PF = 0 to ±1 PF = 1 |
|
| Frequency | 0.1Hz-400kHz, V triggered; Accuracy ±0.1% | - |
| Computed Values | Accuracy; Reactive Power, Var = ±(VA² - W²)½; Apparent Power: VA = Arms Vrms; Power Factor: PF = W/VA; Crest Factor: CF = Ap/Arms, Vp/Vrms; Form Factor: FF = At/Arms, Vt/Vrms; Impedance: Z = Vrms/Arms; Total Harm Dist: THD = (Irms² - IFund²)½/Irms |
Add accuracy percentage figures of values involved in computation. |
| Integrator | Energy, Charge; Accuracy - Wh, VAh, Varh, Ah; Basic accuracy of integrated quantity. | - |
| Harmonic Analysis | Frequency range of fundamental - 2.5Hz-100kHz | - |
| Range of harmonic | 1-99 | |
| Accuracy, Harmonic current and voltage 2Hz-1kHz = ±(0.1% rdg + 0.1% range) 1kHz-10kHz = ±(0.5% rdg + 0.5% range) 10kHz-100kHz = ±(0.7% range + 0.1%/kHz rdg),typical |
- | |
| Display | Blue liquid crystal graphic display with FL backlight; - 64x120mm; - 128x240 pixels | - |
| Power | AC, 50-400Hz; Fuse: Power | 85V-240V; 2A/15VA |
| Dielectric Strength | Inputs to case or power supply Line input to case Input to Input |
2.5kV/50Hz/1 minute 1.5kV/50Hz/1 minute 4kV/50Hz/1 minute |
| Dimension | H x W x D; Weight | 150 x 235 x 320mm; 4kg |
| Options | IEEE-488-2, RS232, Centronics printer output 4 programmable analog outputs, single-, sum-, or average values 4 Analog inputs 0-±5V, input impedance 200kΩ 4 Analog inputs 0-±10V, input impedance 200kΩ Rack mounting kit Windows Operating Software (95 - Vista), transformer-motor testing |
0 - ±5V, accuracy 0.2% 0 - ±5V, accuracy 0.2% 0 - ±10V, accuracy 0.2% |
| 1.5mA-1A Inp Shunt Input |
|
1 A input: set scaling to 0.1 Shunt input: 60mV = 1.0000A |
Screen Shot - Measurement Mode (typ.) |
||||||||||||||||||||||||||||||||||||||||||
Screen Shot - Measurement Value Table |
||||||||||||||||||||||||||||||||||||||||||
Screen Shot - Setup Menu |
||||||||||||||||||||||||||||||||||||||||||
| Back |