| INFRATEK | Switzerland | PC10 Power Converter |
|
|
|
|
| PC10 Models | Specifications | Datasheet |
Turns a PC into a Power Converter |
The new PC10 Spectral Power Converter measures, computes and transmits all your important power variables to your computer. The software lets you select the quantities you want to display on the PC/Notebook monitor. The settings, such as auto or manual ranging are easily changed and measurements are stored at a mouse click. The Spectral Power Converter is available in single or three phase versions and combines an ammeter, voltmeter, wattmeter and a spectrum analyzer in a single light weight package. |
1300 simultaneous values |
From the simultaneous and precise voltage and current measurement you can obtain the RMS, rectified mean, mean, min, max and harmonics through the 99th order. Particular care has been taken to obtain precise power readings (watts, VA, VAR and power factor) at highly distorted signals. Other valus determined are: frequency, crest- and form factor, THD, Wh, VAh, VARh, Ah, harmonics of power, harmonics of impedance (magnitude and phase) and line-to-line voltages. |
High precision, low cost |
The PC10's combination of high frequency performance, excellent common mode rejection and simultaneous measurements is needed for accurate readings on inverter drives, switched mode power supplies and ballast lighting equipment. The current input from 15mA to 40A can be extended to 100A with our option, or you can use your own Hall sensor for current measurements up to 20kA. A shunt input for high frequency current viewing resistors or current clamps is included. Measurement accuracy of 0.1% in a compact, light weight instrument is useful in the laboratory, in the field and in automatic test systems. |
Versatile software package |
The package contains software (DOS or Windows) to control the Spectral Power Converter, read data, display data and store data. Software is available for standard applications in continuous and triggered measurement mode. The software for motor- and transformer testing makes use of the analog inputs to determine mechanical power, torque, speed, slip, corrected power and other values from external transducers. An extensive software driver for LabView is available to build a test system to your needs. |
PC10 Power Converter
| ||||||||||||||||||||
Accessories
| ||||||||||||||||||||
Options
|
| Voltage | Ranges, 8 ranges 1-3-10-sequence; 0.3V, 1V, 3V, 10V, 30V, 100V, 300V, 1000V | - |
| Frequency range | DC, 0.1Hz-1MHz | |
| Crest Factor | 3:1 at 50% full scale (fs) | |
| Input Impedance | >1MΩ | |
| Common Mode - 50Hz/100kHz | 160dB/100dB | |
| Standard accuracy 23°C; rms, mean, rectified mean; 0.3V typical 1Hz-1kHz = ±(0.1% rdg + 0.1% range) DC, 1kHz-10kHz = ±(0.2% rdg + 0.2% range) 10kHz-100kHz = ±(0.3% range + 0.04%/kHz rdg) 100kHz-300kHz = ±(0.3% range + 0.04%/kHz rdg), typical |
Improved accuracy ±(0.05% rdg + 0.07% range ) |
|
| Current | 13 Ranges: 1.5mA, 5mA, 15mA, 50mA, 150mA, 500mA, 1.5A, 5A; 1A, 3A, 10A, 30A, 100A | Max. 1A, 5A, 30A, resp. | ||
| Frequency range | DC, 0.1Hz-300kHz / 1MHz | |||
| Crest Factor | 3:1 at 50% full scale (fs) | |||
| Common Mode - 50Hz/100kHz | 160dB/120dB | |||
|
Lowest ranges 1.5mA, 15mA 1A typical. Improved accuracy 1Hz-400Hz ±(0.05% rdg + 0.07% range) |
|||
| Power | 104 ranges corresponding to the products V x A | - |
| Frequency range | DC, 0.1Hz-300kHz | |
| Accuracy 23°C ±3°C 45Hz-65Hz ±(0.1% rdg + 0.01% range) 1Hz-1kHz Add accuracy percentage figures of current and voltage DC, 1kHz-10kHz +0.04%/kHz PF 10kHz-100kHz |
PF = 0 to ±0.1 PF = 0 to ±1 PF = 0 to ±1 PF = 1 |
|
| Frequency | 0.1Hz-400kHz, V triggered; Accuracy ±0.1% | - |
| Computed Values | Accuracy; Reactive Power, Var = ±(VA² - W²)½; Apparent Power: VA = Arms Vrms; Power Factor: PF = W/VA; Crest Factor: CF = Ap/Arms, Vp/Vrms; Form Factor: FF = At/Arms, Vt/Vrms; Impedance: Z = Vrms/Arms; Total Harm Dist: THD = (Irms² - IFund²)½/Irms |
Add accuracy percentage figures of values involved in computation. |
| Integrator | Energy, Charge; Accuracy - Wh, VAh, Varh, Ah; Basic accuracy of integrated quantity. | - |
| Harmonic Analysis | Frequency range of fundamental - 2.5Hz-100kHz | - |
| Range of harmonic | 1-99 | |
| Accuracy, Harmonic current and voltage 2Hz-1kHz = ±(0.1% rdg + 0.1% range) 1kHz-10kHz = ±(0.5% rdg + 0.5% range) 10kHz-100kHz = ±(0.7% range + 0.1%/kHz rdg),typical |
- | |
| Power | AC, 50-400Hz; Fuse: Power | 85V-240V; 2A/15VA |
| Dielectric Strength | Inputs to case or power supply Line input to case Input to Input |
2.5kV/50Hz/1 minute 1.5kV/50Hz/1 minute 4kV/50Hz/1 minute |
| Dimension | H x W x D; Weight | 150 x 235 x 320mm; 4kg |
| Options | IEEE-488-2, RS232, Centronics printer output 4 programmable analog outputs, single-, sum-, or average values 4 Analog inputs 0-±5V, input impedance 200kΩ 4 Analog inputs 0-±10V, input impedance 200kΩ Rack mounting kit Windows Operating Software (95 - Vista), transformer-motor testing |
0 - ±5V, accuracy 0.2% 0 - ±5V, accuracy 0.2% 0 - ±10V, accuracy 0.2% |
| 1.5mA-1A Inp Shunt Input |
|
1 A input: set scaling to 0.1 Shunt input: 60mV = 1.0000A |