INFRATEK Switzerland 0-200A Current Clamp





0-200A Current Clamp

Back

This current probe is based on Hall Effect technology for use in
measurement of both DC and AC current. The clamp may be
used in conjunction with multimeters, power analyzers and other
suitable equipment for accurate non intrusive current measurement.

SPECIFICATIONS:

Current Ranges:

20 A and 200 A / AC RMS or DC

Measuring Range:

± 30 A and ± 300 A

Output Sensitivity:

10 mV/A (20 A)
1 mV/A (200 A)

Load Impedance:

gr. 10 k Ohms and sm.eq. 100 pF

Accuracy at +25°C....(20A range)
(200A range)

± 1% of reading ± 30 mA
± 1% of reading ± 300 mA

Resolution:

± 10 mA (20 A)
± 100 mA (200 A)

Conductor Position Sensitivity:

± 1.5% relative to centre reading

Frequency Range (small signal):

DC to 10 kHz (-1dB)

Power Supply:

9 V Alkaline, MN1604/PP3
50 Hours, low battery indicator

Temperature Coefficient:

± 0.1% of reading / °C

Working Voltage (see Safety Standards section):

300 V AC RMS or DC


GENERAL CHARACTERISTICS:

Maximum Conductor Size:

19 mm diameter

Output Connection:

4mm safety plugs

Output Zero:

Manual adjust via thumbwheel

Cable length:

1.5 meters

Operating Temperature Range:

0 to +50 °C

Storage Temperature Range (with battery removed):

-20 to +85 °C

Operating Humidity:

15% to 85% (non condensing)

Weight:

250 g

Safety Standards:

BSEN61010-1: 1993 and Amendment A2: July 1995
BSEN61010-2-032: 1995
BSEN61010-2-031: 1995
300 VRMS, Category III, Pollution Degree 2
Use of the probe on uninsulated conductors is limited to 300 V AC RMS or DC and frequencies below 1 kHz.

EMC Standards:

EN61326 :1998


Back